Engineering Installation

Home > After-sale Service > Engineering Installation

Gas fire extinguishing system installation

Operation standard:

GB50116-2013 <fire automatic alarmsystem design>

GB50166-2007 <fire automatic alarmsystem construction and acceptance standard>

GB50370-2005 <gas fire extinguishingdesign standard>

GB50263-2007<gas fire extinguishingsystem construction and acceptance standard>

GB50235-97 <industrial metal pipeline engineering construction and acceptancestandard>

GB/T8163-2008< Transmission fluid withseamless steel tube>

Service content

1. pipe installation and test

2. equipment installation among cylinders

3. installation of fire alarming control system

  

Securitysystem installation

Operating standard

GA/75---94 < safetyprotection engineering system and demand>

GB50348—2004<security standard engineering technology standard>

Service content:

1. pipe installation

2. monitoring equipment installation

3. Security center main equipment installation

 

Fire alarmingsystem installation

 

Operating standard

GB50116-2013  < fire automatic extinguishing systemdesign standard>

GB50166-2007  <fire automatic extinguishing systemconstruction and acceptance standard>

Service content

1. pipe installation

2. fire alarming equiment installation

3. control center installation

  

Fire-proofsealing installation

Operating system:

CECS154-2003  < Building fire blocking applicationprocedures>

Service content:

1. Cable structures in the cable to electric cabinet, tray or openingposition of the control panel, and Tai’s cable through holes in the wall,floor, and work well in the cable pipe hole and fireproof plugging.

2. Cable shaft with other cable structures connected place, floor boardand the fire-proof sealing of a long cable shaft.

3. Outdoor terminal box, power box, control box, cable protection tubedepartment of fireproof plugging.

4. The control room or fire-proof sealing at the entrance of thechannel of distribution device

  

Fire extinguishingproject installation

Operating standard:

GB 50045-95(2005 version)< The codefor fire protection design of tall buildings>

GB 50016-2006 <construction design fireextinguishing standard>

GA95-2007 <fire extinguisher fixing andscrap procedure>

GB50140-2005 < Code for design ofextinguisher disposition>

GB50084-2005 <automatic sprinkers’ fireextinguishing design code>

GB50116-2013<fire extinguishingautomatic alarming system’s design code>

GB50166-2007<fire extinguishingautomatic alarming system’s design code>

GB50166-2007 <fire extinguishing automaticalarming system’s construction and acceptance standard>

Service content

1. Automatic fire alarm and fire linkage control system installation

2.  Automatic fire extinguishing system, includingfoam extinguishing fire, gas, such as automatic spray fire extinguishinginstallation

3.  Indoorand outdoor fire hydrant system installation

4. Smoke exhaust and ventilation air conditioningsystem installation

5. Fire door and activity type fire separationfacilities installation;

6. Fire emergency lighting and evacuationindicating system installation

7. Fire control communication equipment and fireemergency broadcasting system installation

8. Fire power supply and distribution systeminstallation

9.  Firewater system installation

10. Fire extinguishers installation


Contact